Inline 6 Data Link Adapter Kit Heavy Duty Truck Scanner Diagnostic Tool Replacement for Engine

249,00 €
KOSTENLOSER Versand

Inline 6 Data Link Adapter Kit Heavy Duty Truck Scanner Diagnostic Tool Replacement for Engine

  • Marke: Unbranded

Inline 6 Data Link Adapter Kit Heavy Duty Truck Scanner Diagnostic Tool Replacement for Engine

  • Marke: Unbranded
UPE: 329,00 €
Preis: 249,00 €
Sie sparen: 80,00 € (24%)
Verkauft von:
249,00 €
KOSTENLOSER Versand

Auf Lager

Wir akzeptieren die folgenden Zahlungsmethoden

Beschreibung

Feature:1. USB Full Speed Port: INLINE 6 can communicate with your PC via 9pin serial connector. Communication with your PC is also possible via Universal Serial Bus (USB) via a 4pin standard connector.2. Data Link: The INLINE 6 adapter connects to the vehicle power supply, SAE J1708/J1587 data link, and two CAN/J1939 data links via a 25pin serial connector.3. RP1210 Standard: INLINE 6 will work for INSITE, for PowerSpec and for Calterm III software applications. Can also be used with any other software application that is fully RP1210 compliant.4. Easy Use: Each INLINE kit contains a data link adapter, basic cable and INLINE PC software driver. Load the software drivers, connect all the hardware, and you're ready to start a new era of data link adapters.5. Long Durability: Attractive black powder coated aluminum housing provides sturdiness. Rated operating temperature from 40C to +85C meets stringent cab environmental testing requirements.Specification:Item Type: Inline 6 Data Link Adapter KitMaterial: ABS, AluminumFeatures:1. Supports SAE J1708/J1587 and J1939/CAN data links2. Both CAN ports auto detect between 250 and 500 kbps3. Supports USB full speed port at up to 2M baud rate4. USB cable includes thumbscrews for secure mounting to INLINE 65. Supports RS 232 PC serial port at up to 115.2k baud rate6. Fully compliant with TMC's RP1210 standard7. Small enough to fit in pocket8. Attractive black powder coated aluminum housing provides ruggedness9. Derives 8 V to 50 V DC power from vehicle10. Controlled by advanced 140 MHz 32bit for Freescale processor for maximum speed and performance11. Includes 6 LEDs to indicate status of power, USB, RS232, J1708/J1587, and two CAN communication ports12. Both CAN ports support SAE J1939, SAE J2534, and ISO 15765 protocols13. INLINE 6 is certified to meet European CE requirements14. Rated for -40C to + 85C operating temperature15. INLINE 6 meets rigorous in cab environmental test requirementsNote: There are 2 software options in the link, the previous software version is V7.62, and now there is the latest software V8.7. V7.62 software included in the CD.Buyers who choose V8.7 software when placing an order, contact us after receiving the goods, you can provide a link, you need to download it yourselfV8.7 software does not have a registered machine, you need to return the ID, copy, and send it to us for activation.INLINE 6 Quick Start Guide Introduction:The INLINE 6 is a highly reliable datalink adapter that can be used on a wide range of applications to communicate with vehicle systems via SAE J1708/J1587 and SAE J1939 protocols. Please note that the INLINE 6 is designed to be used with RP1210 compliant software.Minimum System RequirementsMicroprocessor: For Pentium 500 MHzMemory: 2 GB CD DriveOperating System: For Win 7, For Vista, For XP SP3To Install the INLINE 6 Software DriverInsert the INLINE 6 driver CD into your computers CD ROM drive.Run INLINE6 Driver Setup.exeIf for Win folder opens, select INLINE6 Driver Setup.exeNote that on some systems the autorun settings may be set to have the installation to just begin executing upon CD insertion.IF YOU SEE: For Win XP, A message appear stating The software you are installing has not passed for WinClick Continue Anyway. Click Finish when installation is complete.To Install the INLINE 6 USB Hardware:To install the INLINE 6 USB hardware, power up the INLINE 6 by plugging in the USB cable provided with the kit to the INLINE 6 and the PC.For Win XP: The Found New Hardware wizard should be displayed.On the first screen, select Install the software automatically (Recommended). Click Next to continue. A message may appear This software has not passed Win Testing......Select Continue Anyway. Click Finish when installation is complete.For Win VISTA/ For Win 7: No action is required. The system tray should display a balloon stating Installing Inline 6.NOTE: If there is a previously installed INLINE 6 driver, you may need to remove the older driver before proceeding.After you have connected your INLINE 6 to your computer and the computer recognizes it as a valid device, you may need to update the firmware in the adapter. Please see the section below on using the INLINE 6 Reflash ToolUsing Your INLINE 6To use the INLINE 6, you must select it from within the application you areusing. Each application has a unique method for selecting datalink adapters.Please refer to the applications documentation for instructions on selectingRP1210 compliant adapters.To Uninstall the INLINE 6 Software DriverFor Win XP: To remove the INLINE 6 driver, click the Start button on the task bar, and then navigate to Control Panel. Navigate to Add or Remove Programs Click on the entry Inline6. Click the Remove button. This will start the uninstall process. Wait until the uninstall process has completed before proceeding. For Win VISTA/ for Win 7: To remove the INLINE 6 driver,click the Start button on the task bar, and then navigate to ControlPanel. Navig
  • Fruugo-ID: 416491400-878837163
  • EAN: 7540131405198

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Produktsicherheitsetiketten

CE Mark
Sicherheitswarnungen: Warning: Please read the product instructions carefully before use to ensure correct use.
Seriennummer: 7540131405198

Lieferung und Rückgaben

Versand innerhalb von 2 Tagen

  • STANDARD: KOSTENLOS - Lieferung zwischen Mi. 08 Oktober 2025–Mi. 15 Oktober 2025 - KOSTENLOS

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • Wuhan Pinsheng Technology Co., Ltd.
  • Wuhan Pinsheng Technology Co., Ltd.
  • No.A357,Shoulder-to-shoulder?Incubator,Building?4
  • Wuchang District
  • Wuhan
  • CN
  • 430000
  • pinsenkj@163.com
  • 18062524796
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795