DC 5-30V LED Display On/Off Relay Module Trigger Cycle Delay Timer Switch

10,95 €
KOSTENLOSER Versand

DC 5-30V LED Display On/Off Relay Module Trigger Cycle Delay Timer Switch

  • Marke: Unbranded
Verkauft von:

DC 5-30V LED Display On/Off Relay Module Trigger Cycle Delay Timer Switch

  • Marke: Unbranded
UPE: 13,95 €
Preis: 10,95 €
Sie sparen: 3,00 € (21%)
Verkauft von:
10,95 €
KOSTENLOSER Versand

Auf Lager

Wir akzeptieren die folgenden Zahlungsmethoden

Beschreibung

Features: 0.1 seconds to 999 minutes continuously adjustable. Wide power supply voltag e (6~30V), supports micro USB 5.0V power supply. One-key emergency stop function, with reverse polarity protection to prevent burn-out. Add sleeping mode, no operation for 5 minutes, automatically turn off the display, and press any button to wake it up. Different OP, CL and LOP parameters can be set, which are independent and saved separately. All setting parameters are automatically saved after power-off. Specification: Supply voltage: DC 6-30V, supports micro USB 5.0v power supply Trigger signal: High level (3.0V-24V) (The signal and system don't use the same GND port) Output capacity: DC 30V/5A, AC 220V/5A Static current: 20mA Working current: 50mA Life: >100,000 times Working temperature: -40~85 ℃ Size: 6.2*3.8*1.7cm / 2.44*1.5*0.67om Weight: Approx. 27g Instruction: 1. Working Mode: P1: After signal triggers, the relay opens for "OP" time, and then disconnect; in the "OP" time, as follows: P1.1: signal is triggered again, invalid P1.2: signal is triggered again, restart the timing P1.3: Give trigger signal, the relay closes for "CL" time, then opens for OP" time; After finishing the timing, disconnect the relay; P3.1: Give trigger signal, the relay opens for "OP" time, then closes for CL" time, then the operation cycles; if give trigger signal again during the cycle, the relay opens, stop timing; the cycles times ( "LOP ") can be set. P3.2: No triggering signal required after power on, the relay opens for "OP" time, then closes for "CL" time, then the operation cycles; the cycles times ( "LOP ") can be set. P-4: Signal holding function: If there is trigger signal, timing is cleared, the relay remains on; when the signal disappears, after "OP" time, the relay is off; if another signal is triggered during timing, timing will be cleared. 2. How to Set Timing Range: After setting the parameter value at mode selection interface, short press "STOP" button to set the timing range; XXX. - timing range: 1 second to 999 seconds. XX.X - timing range: 0.1 seconds to 99.9 seconds X. X. X. - timing range: 1 minute to 999 minutes. 3. Parameter Description: "OP" - on time, "CL" - off time, "LOP" - cycle times (1-999 times, "---" means infinite loop). These parameters are independent of each other, but are shared by each mode. In the main interface (display 000), short press "SET" button will display "OP" ( "CL", "LOP") and the corresponding time XXX; If the mode (such as the mode P1.1, P1.2, P1.3) only has "OP" time, short press the "SET" key to display only the "OP" and the corresponding time; Some models (such as the mode P3.1, P3.2) have parameters "OP", "CL", "LOP", short press "SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times; 4. How to Set Parameters: 1. First, determine the required operating mode. 2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press and hold "SET" button for 2 seconds to enter mode selection interface; then press "UP", "DOWN" button to select the mode (P1.1 ~ P-4). 3. Select the mode (such as P3.2), then press the "SET" button, the parameter to be set flashes ( "OP" on-time, "CL" off time, "LOP" cycles ( "---" represents infinite loop)), press(or press and hold) "UP", "DOWN" button to adjust the parameter value; then press the "STOP" key to set the decimal point position to select the clocking range (0.1 seconds to 999 minutes); press the "SET" button to set the next parameters of the current mode, method is same as above. 4. After the parameters are set, press and hold "SET" button for 2 seconds, then the current mode will flash once, and then return to the main interface, which means the parameters are successfully set. The main interface: If the relay is not in work state, it display "000" with no decimal point), if it is in work state, it has decimal point. Mode selection screen: Press and hold the "SET" button to enter; after setting, press and hold the "SET" button to exit back to the main interface. 5. Relays Enable Mode: 1. ON: Relay allows on in the "OP" on-time; 2. OFF: Relay prohibits on and is always off; In the main interface, press the "STOP" button to switch between ON and OFF, the current state will flash, and then return to the main interface. (This feature is an emergency stop function, press on button to disconnect relay) 6. Sleep Mode: 1. "C-P" Sleep mode: No operation for five minutes, the digital display automatically turns off, the program runs as usual; 2. "O-d" Normal mode: digital display turns on all the time; Press and hold the "STOP" button for two seconds to switch "C-P" and "O-d" state, the current state flashes and then return to the main interface. Package list: 1 * Timer Relay Module
  • Fruugo-ID: 414512784-875674373
  • EAN: 7908770305833

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Produktsicherheitsetiketten

CE Mark
Sicherheitswarnungen: Warning: Please read the product instructions carefully before use to ensure correct use.
Seriennummer: 7908770305833

Lieferung und Rückgaben

Versand innerhalb von 2 Tagen

  • STANDARD: KOSTENLOS - Lieferung zwischen Mo. 13 Oktober 2025–Mo. 20 Oktober 2025 - KOSTENLOS

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795